EVIQUS GmbHTech Preview · Early Access

EVIQUS MonitorQA

EVIQUS MonitorQA is the cross-platform quality-assurance application for DIN 6868-157 acceptance and constancy testing of medical-grade display devices — from radiology reading workstations and mammog…

Type
Software
Deployment
Desktop
Platforms
Windows 10/11, macOS 12+ (Avalonia)
Operation
Offline-capable
Manufacturer
EVIQUS GmbH
01 Technical Data

Specifications

Deployment & license

Deployment
Desktop
License model
Perpetual per Workstation + Annual Maintenance

System requirements

Platforms
Windows 10/11, macOS 12+ (Avalonia)
Operating system (min.)
Windows 10 20H2 / macOS 12 Monterey
Memory (RAM)
4 GB
Disk space
2 GB
Internet required
No

Compliance

Standards & certifications
DIN 6868-157:2022-01-konformes Prüfprotokoll (Anhang C.1/C.2/C.3)
Medical device classification
Standalone-Qualitätssicherungssoftware — kein MDR-Auslöser (nicht-diagnostisch, kein Patientenbezug)
02 Functional scope

Key features

  • DIN 6868-157:2022-01 fully covered — acceptance testing (§8) incl. 9-point homogeneity, half-yearly + daily constancy (§10), classification per Tables 6/7, automatic 20-/30-% rule evaluation
  • Pixel-exact test patterns — TG18-UN10/UN80, TG18-MP, 18-point TG18-LN8 patches, TG18-LPH/LPV line gratings rendered at runtime on the display's native resolution; anatomical patterns (TG18-QC/CT/AD) from the AAPM archive
  • Multi-monitor workflow — automatic detection of all attached displays, single-monitor protection with overlay flow, click-through wizard per display device
  • PAdES-signed test reports — Annex C.1/C.2/C.3 form layouts as native PDF, one RSA-2048 certificate per qualified tester (issued by the EVIQUS portal), optional PAdES-T with RFC 3161 timestamp (FreeTSA / DigiCert / GlobalSign)
  • Half-yearly constancy with baseline tracking — automatic comparison against the last acceptance / baseline run, 18-point characteristic curve only triggered when Table 9 requires it
  • Cross-platform — Windows 10/11 and macOS 12+ (Avalonia 12 / .NET 10), one codebase, identical workflow
  • Portal integration — outbound sync queue with exponential backoff, login backfill, signed-PDF upload, audit trail via EVIQUS portal
  • Offline-capable — tests run locally with a SQLite outbox; portal sync and update checks happen in the background once an internet connection is available
  • Daily reminder + tray mode — app starts minimised to the system tray and brings the main window forward when a daily constancy test is due
  • DIN-cited report labels — all limit values, measurement points and pass/fail wording are cited from DIN 6868-157:2022-01 (Tables 3–9 and Annex C)
  • Integrated feedback and automatic crash reporting — tickets route directly into the EVIQUS support project MQA-FEEDBACK with sanitized log attachments
03 System requirements

System Requirements — EVIQUS MonitorQA

Workstation (minimum)

  • Windows 10 20H2 or higher / Windows 11
  • macOS 12 (Monterey) or higher
  • 4 GB RAM (8 GB recommended for multi-monitor setups)
  • 2 GB free disk space (app + test-pattern cache + local SQLite outbox)
  • CPU: any x64 processor with .NET 10 support (Intel / AMD / Apple Silicon)

Displays

  • At least one reading or mammography monitor under test
  • Recommended: a separate console display for running the wizard (single-monitor setups are supported via an overlay flow — not a blocker)

Photometer (for full acceptance / constancy testing)

  • Any DIN 6868-157-compatible luxmeter / luminance meter (values are entered manually — no proprietary driver required)

Network

  • Internet optional — used only for portal sync, auto-update, qualified-tester certificate retrieval and crash reporting
  • Tests themselves run fully offline; reports are stored locally under ~/Documents/EVIQUS Monitor-QA/

EVIQUS portal (optional, recommended)

  • Account on portal.eviqus.com (provisioned at first install)
  • Customer site is selected once in settings (1 installation = 1 customer site)

Tech-Preview notice

EVIQUS MonitorQA has been running in production with active portal integration for pilot practices since May 2026. The desktop app is currently on the beta update channel; the macOS variant (mqa_osx) is built but not yet released to pilot sites. Auto-update for macOS will follow once the cross-platform EVIQUS.UpdateClient v2.3 ships (roadmap: summer 2026).

04 Description

Cross-platform quality-assurance software for DIN 6868-157 acceptance and constancy testing of medical display devices. Pixel-exact test patterns, qualified-tester-signed PDF reports, portal integration. Beta available.

Interested in EVIQUS MonitorQA?

Let's talk about configuration, price, and delivery.

No sales pitch. We analyse your requirements and propose the right configuration — vendor-neutral.

An unexpected error occurred. Reload 🗙

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.