EVIQUS GmbHTech Preview · Early Access

EVIQUS RAD

EVIQUS RAD is the modern X-ray acquisition workstation for veterinary and human medicine — built for practices and clinics that should not have to choose between veterinary flexibility and human-medic…

Type
Software
Manufacturer
EVIQUS GmbH
01 Technical Data

Specifications

Distribution

Deployment-Modus
Desktop
App-Key
rad

Lizenzierung & Betrieb

Lizenz-Modell
Perpetual per Workstation + Annual Maintenance

Integration & Compliance

Zertifikate
CE-Konformitätsbewertung MDR Class IIb in Vorbereitung, DICOM 3.0 konform

Weitere Eigenschaften

Platforms
Windows 10 (20H2+), Windows 11
Min Os Version
Windows 10 20H2
Min Ram G B
8
Min Disk G B
50
Requires Internet
Nein
Is Commercial Release
Nein
Medical Classification
Class IIb (MDR Annex VIII Rule 11) — Tech-Preview, pre-submission
Key Features
- **One platform for vet and human** — practice mode chosen at install, fully localised (DE/EN, more languages extensible) - **Detector-agnostic** — Thales PixRad (3543DRcs, EZ, EZX, EZhd), Careray CareView, PZ Medical and more; AED + SW-Sync; image recovery so no image is lost - **Generator integration** — Powersite, Spellman, Siemens Polydoros, or manual values (post-APR dialog) - **DICOM-native** — Modality Worklist (C-FIND), Send-to-PACS (C-STORE with retry queue & network monitoring), MPPS, DICOMDIR & JPEG export, MONOCHROME1-compliant pixel data - **Radiation protection per German law** — BfS 2022 DRL & §122 StrlSchV, BÄK 2022 acquisition-technique validation, §83/§85 pregnancy check, EXI/DI per IEC 62494-1 - **Paediatric safety** — age-group-specific APR trees, collimation reminders, filtration warnings for trunk exposures - **Anatomically sorted APR templates** — over 130 projections with BÄK-compliant defaults, inheritance-based APR hierarchy per patient size - **Imaging tools** — real-time window/level, annotations (markers, text, distance/angle measurements in mm), re-review, multi-grid viewer, crop-to-collimation - **Exposure journal (Röntgenbuch)** — sequential documentation of all acquisitions with CSV export - **Offline-capable** — acquisition runs locally; PACS connection via LAN; no mandatory cloud - **Image recovery** — self-healing pipeline for all supported detectors — no lost images - **Built-in feedback** — quick feedback and automatic crash reporting directly to EVIQUS support
System Requirements Detail
## System Requirements — EVIQUS RAD ### Workstation (Minimum) - Windows 10 20H2 or higher / Windows 11 - 8 GB RAM (16 GB recommended for large images & real-time processing) - 50 GB free disk space for image cache (scales with study volume) - CPU: Intel Core i5 / AMD Ryzen 5 (8th generation or newer) - Display: 1920×1080 (medical-grade diagnostic monitors recommended) - USB / Gigabit Ethernet for detector connection ### Database - PostgreSQL 12+ (recommended for production) or - SQLite (for demo / portable installations) ### Network - LAN connection for PACS / DICOM Worklist (optional, depending on workflow) - Internet only for updates and support feedback (not required for acquisition) ### Supported Hardware - **Detectors**: Thales PixRad series (3543DRcs, EZ, EZX, EZhd), Careray CareView, PZ Medical - **Generators**: Powersite, Spellman, Siemens Polydoros RF/RFX, or manual entry without generator connection ### Tech-Preview Notice RAD is currently in a supported Tech-Preview phase. MDR conformity assessment (Class IIb) is in preparation; CE marking has not yet been issued. Pilot installations are possible on request.
02 Description

X-ray acquisition software for veterinary and human medicine. Detector-agnostic, DICOM-native, radiation-protection-compliant. Tech-Preview available.

Interested in EVIQUS RAD?

Let's talk about configuration, price, and delivery.

No sales pitch. We analyse your requirements and propose the right configuration — vendor-neutral.